4 × 8 TB in RAID 10

Usable space, rebuild time and read error risk for 4 drives of 8 TB each.

4 × 8 TB drives in RAID 10 give 16 TB of usable space, which Windows shows as 14.6 TB. 16 TB goes to mirror copies, so 50% of the 32 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 67% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
16TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 8 TB in RAID 10
Raw32 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 8 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
32 TB
100%
None
—
—
8 TB
25%
Any 3
14 h
Fixed by another copy
24 TB
75%
Any 1
14 h
17%
16 TB
50%
Any 2
14 h
Fixed by parity
16 TB
50%
1 to 2
14 h
6.2%
Needs at least 6 drives
Needs at least 8 drives

4 × 8 TB in RAID 10: the numbers

Usable space16 TB (14.6 TB in Windows)
Raw space32 TB
Used for protection16 TB
Efficiency50%
Drives that can fail1 to 2
Rebuild at 150 MB/s14 h
Rebuild at 50 MB/s (busy)44 h
Data read during rebuild8 TB
Read error risk, desktop drives47%
Read error risk, NAS drives6.2%

Rebuild

Replacing a failed drive means writing a full 8 TB drive. At 150 MB/s with no other load that takes about 14 h; on a busy array running at 50 MB/s, about 44 h. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 8 TB, the chance of at least one unreadable sector is 47% with desktop drives (1 per 1014 bits) and 6.2% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With four drives, RAID 6 gives the same 16 TB and survives any two failures. RAID 10 writes faster and rebuilds faster.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144