10 × 2 TB in RAID 10

Usable space, rebuild time and read error risk for 10 drives of 2 TB each.

10 × 2 TB drives in RAID 10 give 10 TB of usable space, which Windows shows as 9.1 TB. 10 TB goes to mirror copies, so 50% of the 20 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 89% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
10TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing10 × 2 TB in RAID 10
Raw20 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

10 drives of 2 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
20 TB
100%
None
—
—
2 TB
10%
Any 9
3 h 42 min
Fixed by another copy
18 TB
90%
Any 1
3 h 42 min
13%
16 TB
80%
Any 2
3 h 42 min
Fixed by parity
10 TB
50%
1 to 5
3 h 42 min
1.6%
16 TB
80%
1 to 2
3 h 42 min
6.2%
12 TB
60%
2 to 4
3 h 42 min
Fixed by parity

10 × 2 TB in RAID 10: the numbers

Usable space10 TB (9.1 TB in Windows)
Raw space20 TB
Used for protection10 TB
Efficiency50%
Drives that can fail1 to 5
Rebuild at 150 MB/s3 h 42 min
Rebuild at 50 MB/s (busy)11 h
Data read during rebuild2 TB
Read error risk, desktop drives15%
Read error risk, NAS drives1.6%

Rebuild

Replacing a failed drive means writing a full 2 TB drive. At 150 MB/s with no other load that takes about 3 h 42 min; on a busy array running at 50 MB/s, about 11 h. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 2 TB, the chance of at least one unreadable sector is 15% with desktop drives (1 per 1014 bits) and 1.6% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 10 drives, RAID 6 gives more space (16 TB instead of 10 TB) and survives any two failures. RAID 10 is the better pick for databases and virtual machines that write many small blocks.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144