12 × 18 TB in RAID 10

Usable space, rebuild time and read error risk for 12 drives of 18 TB each.

12 × 18 TB drives in RAID 10 give 108 TB of usable space, which Windows shows as 98.2 TB. 108 TB goes to mirror copies, so 50% of the 216 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 91% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
108TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing12 × 18 TB in RAID 10
Raw216 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

12 drives of 18 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
216 TB
100%
None
—
—
18 TB
8%
Any 11
33 h
Fixed by another copy
198 TB
92%
Any 1
33 h
79%
180 TB
83%
Any 2
33 h
Fixed by parity
108 TB
50%
1 to 6
33 h
13%
180 TB
83%
1 to 2
33 h
51%
144 TB
67%
2 to 4
33 h
Fixed by parity

12 × 18 TB in RAID 10: the numbers

Usable space108 TB (98.2 TB in Windows)
Raw space216 TB
Used for protection108 TB
Efficiency50%
Drives that can fail1 to 6
Rebuild at 150 MB/s33 h
Rebuild at 50 MB/s (busy)4.2 days
Data read during rebuild18 TB
Read error risk, desktop drives76%
Read error risk, NAS drives13%

Rebuild

Replacing a failed drive means writing a full 18 TB drive. At 150 MB/s with no other load that takes about 33 h; on a busy array running at 50 MB/s, about 4.2 days. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 18 TB, the chance of at least one unreadable sector is 76% with desktop drives (1 per 1014 bits) and 13% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 12 drives, RAID 6 gives more space (180 TB instead of 108 TB) and survives any two failures. RAID 10 is the better pick for databases and virtual machines that write many small blocks.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144