4 × 6 TB in RAID 10: the numbers
| Usable space | 12 TB (10.9 TB in Windows) |
|---|---|
| Raw space | 24 TB |
| Used for protection | 12 TB |
| Efficiency | 50% |
| Drives that can fail | 1 to 2 |
| Rebuild at 150 MB/s | 11 h |
| Rebuild at 50 MB/s (busy) | 33 h |
| Data read during rebuild | 6 TB |
| Read error risk, desktop drives | 38% |
| Read error risk, NAS drives | 4.7% |
Rebuild
Replacing a failed drive means writing a full 6 TB drive. At 150 MB/s with no other load that takes about 11 h; on a busy array running at 50 MB/s, about 33 h. Only the mirror partner is read, so the other drives are not stressed.
Read errors
Reading 6 TB, the chance of at least one unreadable sector is 38% with desktop drives (1 per 1014 bits) and 4.7% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.
Our take
With four drives, RAID 6 gives the same 12 TB and survives any two failures. RAID 10 writes faster and rebuilds faster.