10 × 20 TB in RAID 10

Usable space, rebuild time and read error risk for 10 drives of 20 TB each.

10 × 20 TB drives in RAID 10 give 100 TB of usable space, which Windows shows as 90.9 TB. 100 TB goes to mirror copies, so 50% of the 200 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 89% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
100TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing10 × 20 TB in RAID 10
Raw200 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

10 drives of 20 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
200 TB
100%
None
—
—
20 TB
10%
Any 9
37 h
Fixed by another copy
180 TB
90%
Any 1
37 h
76%
160 TB
80%
Any 2
37 h
Fixed by parity
100 TB
50%
1 to 5
37 h
15%
160 TB
80%
1 to 2
37 h
47%
120 TB
60%
2 to 4
37 h
Fixed by parity

10 × 20 TB in RAID 10: the numbers

Usable space100 TB (90.9 TB in Windows)
Raw space200 TB
Used for protection100 TB
Efficiency50%
Drives that can fail1 to 5
Rebuild at 150 MB/s37 h
Rebuild at 50 MB/s (busy)4.6 days
Data read during rebuild20 TB
Read error risk, desktop drives80%
Read error risk, NAS drives15%

Rebuild

Replacing a failed drive means writing a full 20 TB drive. At 150 MB/s with no other load that takes about 37 h; on a busy array running at 50 MB/s, about 4.6 days. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 20 TB, the chance of at least one unreadable sector is 80% with desktop drives (1 per 1014 bits) and 15% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 10 drives, RAID 6 gives more space (160 TB instead of 100 TB) and survives any two failures. RAID 10 is the better pick for databases and virtual machines that write many small blocks.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144