6 × 18 TB in RAID 6

Usable space, rebuild time and read error risk for 6 drives of 18 TB each.

6 × 18 TB drives in RAID 6 give 72 TB of usable space, which Windows shows as 65.5 TB. 36 TB goes to parity, so 67% of the 108 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
72TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing6 × 18 TB in RAID 6
Raw108 TB
Efficiency67%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

6 drives of 18 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
108 TB
100%
None
—
—
18 TB
17%
Any 5
33 h
Fixed by another copy
90 TB
83%
Any 1
33 h
51%
72 TB
67%
Any 2
33 h
Fixed by parity
54 TB
50%
1 to 3
33 h
13%
72 TB
67%
1 to 2
33 h
25%
Needs at least 8 drives

6 × 18 TB in RAID 6: the numbers

Usable space72 TB (65.5 TB in Windows)
Raw space108 TB
Used for protection36 TB
Efficiency67%
Drives that can failAny 2
Rebuild at 150 MB/s33 h
Rebuild at 50 MB/s (busy)4.2 days
Data read during rebuild90 TB
Read error risk, desktop drivesover 99% (corrected)
Read error risk, NAS drives51% (corrected)

Rebuild

Replacing a failed drive means writing a full 18 TB drive. At 150 MB/s with no other load that takes about 33 h; on a busy array running at 50 MB/s, about 4.2 days. The rebuild reads every surviving drive: 90 TB in total.

Read errors

Reading 90 TB, the chance of at least one unreadable sector is over 99% with desktop drives (1 per 1014 bits) and 51% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

For 18 TB drives this is the setup most administrators would choose: the rebuild takes 33 h, and the array stays protected the whole time.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240