5 × 4 TB in RAID 6

Usable space, rebuild time and read error risk for 5 drives of 4 TB each.

5 × 4 TB drives in RAID 6 give 12 TB of usable space, which Windows shows as 10.9 TB. 8 TB goes to parity, so 60% of the 20 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
12TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing5 × 4 TB in RAID 6
Raw20 TB
Efficiency60%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

5 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
20 TB
100%
None
—
—
4 TB
20%
Any 4
7 h 24 min
Fixed by another copy
16 TB
80%
Any 1
7 h 24 min
12%
12 TB
60%
Any 2
7 h 24 min
Fixed by parity
RAID 10 +1 spare
8 TB
40%
1 to 2
7 h 24 min
3.1%
Needs at least 6 drives
Needs at least 8 drives

5 × 4 TB in RAID 6: the numbers

Usable space12 TB (10.9 TB in Windows)
Raw space20 TB
Used for protection8 TB
Efficiency60%
Drives that can failAny 2
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild16 TB
Read error risk, desktop drives72% (corrected)
Read error risk, NAS drives12% (corrected)

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. The rebuild reads every surviving drive: 16 TB in total.

Read errors

Reading 16 TB, the chance of at least one unreadable sector is 72% with desktop drives (1 per 1014 bits) and 12% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

With 4 TB drives, RAID 5 would give 16 TB with a rebuild of 7 h 24 min. RAID 6 is still the safer choice for data you cannot replace.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240