8 × 6 TB in RAID 5

Usable space, rebuild time and read error risk for 8 drives of 6 TB each.

8 × 6 TB drives in RAID 5 give 42 TB of usable space, which Windows shows as 38.2 TB. 6 TB goes to parity, so 88% of the 48 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
42TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing8 × 6 TB in RAID 5
Raw48 TB
Efficiency88%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

8 drives of 6 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
48 TB
100%
None
—
—
6 TB
13%
Any 7
11 h
Fixed by another copy
42 TB
88%
Any 1
11 h
29%
36 TB
75%
Any 2
11 h
Fixed by parity
24 TB
50%
1 to 4
11 h
4.7%
36 TB
75%
1 to 2
11 h
13%
24 TB
50%
2 to 4
11 h
Fixed by parity

8 × 6 TB in RAID 5: the numbers

Usable space42 TB (38.2 TB in Windows)
Raw space48 TB
Used for protection6 TB
Efficiency88%
Drives that can failAny 1
Rebuild at 150 MB/s11 h
Rebuild at 50 MB/s (busy)33 h
Data read during rebuild42 TB
Read error risk, desktop drives97%
Read error risk, NAS drives29%

Rebuild

Replacing a failed drive means writing a full 6 TB drive. At 150 MB/s with no other load that takes about 11 h; on a busy array running at 50 MB/s, about 33 h. The rebuild reads every surviving drive: 42 TB in total.

Read errors

Reading 42 TB, the chance of at least one unreadable sector is 97% with desktop drives (1 per 1014 bits) and 29% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 8 drives sharing one parity, a second failure during the rebuild gets more likely. RAID 6 gives 36 TB with two-drive protection. RAID 10 with the same drives gives 24 TB, faster writes and shorter rebuilds.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168